Outdoor Non-Intumescent Fireproof Coating for Steel Structure – Outdoor non-intumescent fireproof coating for steel structures.
3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.
Bond strength test result: 0.11 MPa.
Fire test: 33 mm thickness; 5400 mm span; 3.00 h.
Special Outdoor Non-Intumescent Fireproof Coating for Steel Structure – Special cementitious coating for hydrocarbon-flame fire protection.
For petrochemical/chemical outdoor steel structures.
3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.
Air spray 0.6–0.8 MPa; nozzle Φ4.0–6.0 mm.
Outdoor Intumescent Fireproof Coating for Steel Structure – Waterborne intumescent coating for outdoor steel fire protection.
2 h rating: ≥3.2 mm; 4.5 kg/m² theoretical consumption.
Air spray 0.6–0.8 MPa; nozzle Φ4.0–6.0 mm.
Bond strength test result: 0.77 MPa.
New polymer anti-corrosion coating (2K) for water, oil, and sewage pipelines.
Municipal water, circulating water, sewage, oil pipelines.
Recoat 12 h–7 d; pot life 4 h.
Resists acids/alkalis/salts; seawater resistance.
Epoxy bitumen cooling tower damp-proof coating (2K) for cooling tower inner wall protection.
For cooling towers, sewage tanks, underground mines.
Mixing ratio 25:2.5; pot life 4 h.
Waterproof, anti-seepage, and mildew resistant.
Polyurethane engineering machinery topcoat (2K) for abrasion-resistant equipment finishing.
Cranes, excavators, bulldozers, mining equipment.
0.1 kg/m² at 30 µm; pot life 4 h.
System: HS06-1 primer + HS04-1 topcoat.
Polyurethane anti-corrosion primer (2K) for heavy construction equipment steel.
Cranes, excavators, bulldozers, mining machinery.
0.13 kg/m² at 40 µm; pot life 4 h.
System: HS06-1 primer + HS04-1 topcoat.
Acid-resistant coating (2K) for harsh chemical plants and pickling lines.
Pickling, galvanizing, electroplating, petrochemical sites.
Mix ratio 21:7; pot life 4 h.
Resists acids, alkalis, salts, chemical atmospheres.
Polymer interpenetrating network coating (2K) for long-term anti-corrosion on steel/concrete.
Pipelines, tanks, gas holders, cooling towers.
Mix ratio 4:1; pot life 4 h.
Service temperature range: -20 to 120°C.
CSPE cooling tower damp-proof coating for inner wall anti-corrosion service.
For cooling tower inner wall protection.
Single-component; min recoat 12 h at 25°C.
Resists freeze-thaw, damp heat, and mildew.
Wet gas holder dedicated anti-corrosion coating (2K) for wet-type gas holder protection.
Dedicated for wet gas holders.
Pot life 3 h; recoat 24 h–7 d.
Primer/intermediate/topcoat system; H2S resistance.
Road marking coating for high-visibility lines on roads and parking areas.
Highways, city roads, parking lots, factory roads.
No-track time ≤20 min; recoat from 6 h.
Single-component; airless spray or roller.
Heat-reflective thermal insulation coating (2K) for cooling and corrosion protection of exteriors.
Metal tanks, LPG tanks, tank trucks, buildings.
Pot life 3 h; recoat 24 h–7 d.
Primer/intermediate/topcoat system; white/light topcoat.
Chlorinated rubber waterline coating for ship hull waterline zones.
Waterline protection and decoration.
0.16 kg/m² at 40 µm DFT.
Recoat after 9 h; max interval unlimited.
Chlorinated rubber deck coating for ship deck protection and slip resistance.
Ship deck surfaces.
0.14 kg/m² at 40 µm DFT.
Single-pack; 101 thinner 3–8%.
Chlorinated rubber acrylic hull coating for above-waterline ship hull finishing.
Hull exterior above the waterline.
0.16 kg/m² at 40 µm DFT.
Recoat after 8 h; max interval unlimited.