Industrial Coatings & Anti-Corrosion Systems | Product Catalog – HUILI
Indoor Non-Intumescent Fireproof Coating for Steel Structure – Indoor cementitious thermal-insulation fireproof coating for steel.
3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.
Air spray 0.6–0.8 MPa; nozzle Φ4.0–6.0 mm.
Fire test: 32 mm thickness; 5400 mm span; 3.00 h.
Indoor Intumescent Fireproof Coating for Steel Structure – Waterborne intumescent coating for indoor steel fire protection.
2 h rating: ≥3.3 mm; 4.6 kg/m² theoretical consumption.
Water-thinnable; max dilution 5%.
Bond strength test result: 0.82 MPa.
Outdoor Non-Intumescent Fireproof Coating for Steel Structure – Outdoor non-intumescent fireproof coating for steel structures.
3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.
Bond strength test result: 0.11 MPa.
Fire test: 33 mm thickness; 5400 mm span; 3.00 h.
Special Outdoor Non-Intumescent Fireproof Coating for Steel Structure – Special cementitious coating for hydrocarbon-flame fire protection.
For petrochemical/chemical outdoor steel structures.
3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.
Air spray 0.6–0.8 MPa; nozzle Φ4.0–6.0 mm.
Outdoor Intumescent Fireproof Coating for Steel Structure – Waterborne intumescent coating for outdoor steel fire protection.
2 h rating: ≥3.2 mm; 4.5 kg/m² theoretical consumption.
Air spray 0.6–0.8 MPa; nozzle Φ4.0–6.0 mm.
Bond strength test result: 0.77 MPa.
Epoxy bitumen cooling tower damp-proof coating (2K) for cooling tower inner wall protection.
For cooling towers, sewage tanks, underground mines.
Mixing ratio 25:2.5; pot life 4 h.
Waterproof, anti-seepage, and mildew resistant.
CSPE cooling tower damp-proof coating for inner wall anti-corrosion service.
For cooling tower inner wall protection.
Single-component; min recoat 12 h at 25°C.
Resists freeze-thaw, damp heat, and mildew.
Acrylic high-build topcoat for steel, concrete, and above-waterline ship areas.
For steel structures, concrete, and building walls.
Single-pack; min recoat 12 h at 25°C.
Thinner X-14; dilution 3–7%.
Modified acrylic topcoat for steel, concrete, and building protective finishing.
For power, metallurgy, machinery, transportation structures.
Single-pack; min recoat 12 h at 25°C.
Thinner X-14; dilution 3–7%.
Long-lasting special marking coating for chimney and tower marking/protection.
For steel structures and concrete chimneys.
Single-component; min recoat 24 h at 25°C.
Gloss ≥80; dry to touch 1 h.
Premium acrylic marking coating for chimney and steel tower marking.
For power plant concrete chimneys and steel towers.
Single-component; min recoat 12 h at 25°C.
Thinner X-14; dilution 3–7%.
Acrylic polyurethane topcoat (2K) for bridges, tanks, containers, and port machinery.
For large bridges, gates, tanks, steel towers.
Mixing ratio 18:3; pot life 3 h.
Compatible over zinc-rich and epoxy MIO intermediates.
Inorganic Zinc Silicate Primer (2K) – Two-component inorganic zinc silicate primer for long-term steel corrosion protection with cathodic protection.
For blast-cleaned steel; surface preparation Sa 3 (not lower than Sa 2.5) is specified.
Fast drying at 25°C, RH 70–85%: touch dry 10 min; hard dry 2 h; cured 24 h.
Mix ratio 28:7; thinner X-11 inorganic zinc thinner (5–20%); compatible with epoxy/PU coating systems.
Inorganic Zinc-Rich Primer (2K) – Two-component ethyl silicate zinc-rich primer for cathodic protection of blast-cleaned steel.
General-purpose use for bridges, towers, gas holders, oil tanks, oil/gas pipelines, and industrial steel structures.
High zinc dust content with stated water/oil/media resistance and welding/cutting resistance.
Sa 3 surface preparation (not lower than Sa 2.5); touch dry 10 min at 25°C, RH 70–85%.
Perchloroethylene anti-corrosion coating for equipment, metal structures, and concrete.
For mechanical equipment, metal structures, concrete surfaces.
Single-component; min recoat 12 h at 25°C.
Primer/topcoat system available under PLG52.
Perchloroethylene enamel for mechanical equipment and metal parts finishing.
For protective and decorative finishing on metals.
Single-component; min recoat 12 h at 25°C.
Thinner X-1; dilution 3–7%.