Acrylic high-build topcoat for steel, concrete, and above-waterline ship areas.
For steel structures, concrete, and building walls.
Single-pack; min recoat 12 h at 25°C.
Thinner X-14; dilution 3–7%.
Overview
Single-pack acrylic high-build topcoat with good abrasion and impact resistance.
Provides resistance to seawater, mineral oil, and animal/vegetable oils, with weathering, color retention, and gloss retention.
Composition
Formulated with acrylic resin, plasticizer, weather-resistant pigments, fillers, additives, and solvents.
Typical uses
Protective topcoat for steel structures and concrete.
Also suitable for ship topside and above-waterline areas, and as protective/decorative finishing for building walls.
Technical data (typical)
Appearance: Various colors.
Theoretical consumption: 0.24 kg/m² at 60 μm DFT (excluding loss).
Density: 1.2 kg/L.
Solids: 80% (by weight); 65% (by volume).
Drying time (25°C): Surface dry 0.5 h; hard dry 2 h.
Application data (25°C)
Mixing: Single-pack.
Induction time: None.
Pot life: Unlimited.
Application methods: Airless spray, brush, roller.
Thinner: X-14 acrylic thinner; dilution 3–7%.
Recoat interval (25°C): Min 12 h; max unlimited.
Recommended coats / DFT: 1 coat 30–60 μm; brush/roller 1 coat 30–40 μm.
Surface preparation
Remove dust and oil contamination from the previous coat; if beyond maximum recoat interval, consider roughening as needed.
When used as the first coat: blast/shot blast to Sa 2.5 or power-tool cleaning to St 3; surface profile 30–75 μm.
System compatibility / packing / storage
Compatibility: Previous coat—epoxy primer; epoxy intermediate coating; chlorinated rubber anti-rust coating; acrylic anti-rust coating.
Packing: 22 kg.
Storage: Shelf life 12 months; store dry/cool/ventilated, away from fire and direct sunlight; no outdoor stacking.
We would love to speak with you.
Feel free to reach out using the below details.
Indoor Intumescent Fireproof Coating for Steel Structure – Waterborne intumescent coating for indoor steel fire protection.
2 h rating: ≥3.3 mm; 4.6 kg/m² theoretical consumption.
Water-thinnable; max dilution 5%.
Bond strength test result: 0.82 MPa.
Inorganic Zinc-Rich Primer (2K) – Two-component ethyl silicate zinc-rich primer for cathodic protection of blast-cleaned steel.
General-purpose use for bridges, towers, gas holders, oil tanks, oil/gas pipelines, and industrial steel structures.
High zinc dust content with stated water/oil/media resistance and welding/cutting resistance.
Sa 3 surface preparation (not lower than Sa 2.5); touch dry 10 min at 25°C, RH 70–85%.
Epoxy Glass Flake Intermediate Coating (2K) – Two-component epoxy glass flake intermediate coating for heavy-duty barrier protection.
For marine/offshore, chemical areas, underground mines, and wastewater facilities; steel and concrete substrates.
Mix ratio 25:2.5; pot life 4 h (25°C).
Recoat 24 h–7 d (25°C); recommended DFT 60–80 µm per coat.
Epoxy Zinc Primer (2K, C6-Modified) – Two-component epoxy zinc primer (C6-modified) for cathodic-protection priming.
Salt spray resistance 1300 h (as stated).
Theoretical consumption 0.25 kg/m² at 50 µm DFT (losses not included).
For offshore platforms, underwater steel, pipelines, oil tanks, bridges, and petrochemical steel structures.
Protect. Perform. Endure. – Advanced Coatings for Industrial Excellence.