Long-lasting special marking coating for chimney and tower marking/protection.
For steel structures and concrete chimneys.
Single-component; min recoat 24 h at 25°C.
Gloss ≥80; dry to touch 1 h.
Overview
Single-component special marking coating for long-lasting marking and protection.
Designed with weathering resistance and heat/cold resistance, with stated service life over 10 years.
Composition
Formulated with premium acrylic resin, silicone resin, imported premium pigments, solvents, and additives.
Typical uses
For protection and marking of steel structures and concrete chimneys, and for marking/protection of large steel towers.
Technical data (typical)
Appearance: White; bright red, etc.
Theoretical consumption: 0.16 kg/m² at 40 μm DFT (excluding loss).
Density: 1.2 kg/L.
Drying time (25°C): Surface dry 1 h; hard dry 8 h.
Gloss: ≥80.
Application data (25°C)
Mixing: Single-component.
Induction time: None.
Pot life: Unlimited.
Application methods: Airless spray, brush, roller.
Thinner: PLB83 dedicated thinner; dilution 3–7%.
Recoat interval (25°C): Min 24 h; max unlimited.
Recommended coats / DFT: 1 coat 40–60 μm; brush/roller 1 coat 30–40 μm.
Surface preparation
Steel: blast/shot blast to Sa 2.5 or power-tool cleaning to St 3; surface profile 30–75 μm.
Concrete: must be dry (moisture content ≤6%), free of oil/contamination; apply after a sealing primer; for old coatings, consider roughening and remove chalked/loose areas.
System compatibility / packing / storage
Packing: 20 kg.
Storage: Shelf life 12 months; store dry/cool/ventilated, away from fire and direct sunlight; no outdoor stacking.
We would love to speak with you.
Feel free to reach out using the below details.
Outdoor Non-Intumescent Fireproof Coating for Steel Structure – Outdoor non-intumescent fireproof coating for steel structures.
3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.
Bond strength test result: 0.11 MPa.
Fire test: 33 mm thickness; 5400 mm span; 3.00 h.
Indoor Intumescent Fireproof Coating for Steel Structure – Waterborne intumescent coating for indoor steel fire protection.
2 h rating: ≥3.3 mm; 4.6 kg/m² theoretical consumption.
Water-thinnable; max dilution 5%.
Bond strength test result: 0.82 MPa.
Vinyl Phosphating Primer (2K) – Two-component phosphating primer for galvanized steel, aluminum, and other light metals.
Forms chemical adhesion to improve intercoat adhesion of subsequent coatings.
Low film thickness system: 15–25 µm DFT per coat; theoretical consumption 0.06 kg/m² at 20 µm DFT.
Min. recoat 2 h (25°C); dedicated PLX06 thinner (10–20%).
Epoxy Glass Flake Intermediate Coating (2K) – Two-component epoxy glass flake intermediate coating for heavy-duty barrier protection.
For marine/offshore, chemical areas, underground mines, and wastewater facilities; steel and concrete substrates.
Mix ratio 25:2.5; pot life 4 h (25°C).
Recoat 24 h–7 d (25°C); recommended DFT 60–80 µm per coat.
Protect. Perform. Endure. – Advanced Coatings for Industrial Excellence.