Epoxy bitumen cooling tower damp-proof coating (2K) for cooling tower inner wall protection.
For cooling towers, sewage tanks, underground mines.
Mixing ratio 25:2.5; pot life 4 h.
Waterproof, anti-seepage, and mildew resistant.
Overview
Two-component epoxy bitumen damp-proof coating system for cooling tower inner walls.
Provides impermeability, waterproofing, mildew resistance, corrosion resistance, and heat resistance.
Composition
Formulated with epoxy resin, bitumen, lamellar fillers, solvents, and additives.
Cured with modified amine; supplied in Part A & Part B packs.
Typical uses
Protection of cooling tower inner walls, and waterproof/anti-corrosion for sewage tanks and underground mines.
Technical data (typical)
Appearance: Primer—red-brown; topcoat—black.
Theoretical consumption: 0.17 kg/m² at 60 μm DFT (excluding loss).
Density: 1.3 kg/L.
Drying time (25°C): Surface dry 1 h; hard dry 24 h; fully cured 7 d.
Application data (25°C)
Mixing ratio (Part A:Part B): 25:2.5.
Induction time: 5 min.
Pot life: 4 h.
Application methods: Airless spray, brush, roller.
Thinner: X-7 epoxy thinner; dilution 3–7%.
Recoat interval (25°C): Min 12 h; max unlimited.
Recommended coats / DFT: 1 coat 40–60 μm; brush/roller 1 coat 30–40 μm.
Surface preparation
Steel: blast/shot blast to Sa 2.5 or power-tool cleaning to St 3; surface profile 30–75 μm.
Concrete: must be sound and dry (moisture content ≤6%), free of contamination; repair defects and wash/de-alkalize, dry, then apply after a sealing primer.
System compatibility / packing / storage
Packing: Part A 25 kg; Part B 2.5 kg.
Storage: Shelf life 12 months; store dry/cool/ventilated, away from fire and direct sunlight; no outdoor stacking.
We would love to speak with you.
Feel free to reach out using the below details.
Outdoor Non-Intumescent Fireproof Coating for Steel Structure – Outdoor non-intumescent fireproof coating for steel structures.
3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.
Bond strength test result: 0.11 MPa.
Fire test: 33 mm thickness; 5400 mm span; 3.00 h.
Outdoor Intumescent Fireproof Coating for Steel Structure – Waterborne intumescent coating for outdoor steel fire protection.
2 h rating: ≥3.2 mm; 4.5 kg/m² theoretical consumption.
Air spray 0.6–0.8 MPa; nozzle Φ4.0–6.0 mm.
Bond strength test result: 0.77 MPa.
Inorganic Zinc Silicate Primer (2K) – Two-component inorganic zinc silicate primer for long-term steel corrosion protection with cathodic protection.
For blast-cleaned steel; surface preparation Sa 3 (not lower than Sa 2.5) is specified.
Fast drying at 25°C, RH 70–85%: touch dry 10 min; hard dry 2 h; cured 24 h.
Mix ratio 28:7; thinner X-11 inorganic zinc thinner (5–20%); compatible with epoxy/PU coating systems.
Epoxy MIO intermediate coating (2K) for barrier protection in cathodic-protection coating systems.
Used with PLH53-35 epoxy zinc primer as a supporting intermediate coat.
Salt water resistance: 20 days (as stated).
Mixing ratio 8:1 (by weight); recommended DFT 60–90 µm per coat.
Protect. Perform. Endure. – Advanced Coatings for Industrial Excellence.