S55-2 Polyurethane cooling tower damp-proof coating (primer/topcoat)

Polyurethane cooling tower damp-proof coating (2K) for waterproof anti-corrosion lining.

  • For cooling towers, sewage tanks, mines, underground buildings.

  • Primer ratio 24:3; topcoat ratio 18:3.

  • Pot life 4 h; min recoat 12 h.

S55-2 Polyurethane cooling tower damp-proof coating (primer/topcoat) Descriotion

Overview
Two-component polyurethane damp-proof coating system for waterproofing and anti-corrosion.
Provides strong adhesion, water resistance, damp-heat resistance, corrosion resistance, and mildew resistance.

Composition
Formulated with polyurethane resin, impermeability pigments, anti-rust pigments, reinforcing materials, solvents, and additives.
Cured with polyisocyanate; supplied in Part A & Part B packs.

Typical uses
Waterproof and anti-corrosion for concrete structures and steel structures, including cooling towers, sewage tanks, mines, and underground buildings.

Technical data (typical)

  • Appearance: Primer—brown; topcoat—grey.

  • Theoretical consumption: Primer 0.16 kg/m² at 50 μm DFT; topcoat 0.13 kg/m² at 40 μm DFT (excluding loss).

  • Density: Primer 1.4 kg/L; topcoat 1.2 kg/L.

  • Drying time (25°C): Surface dry 1 h; hard dry 24 h; fully cured 7 d.

Application data (25°C)

  • Mixing ratio (Part A:Part B): Primer 24:3; topcoat 18:3.

  • Induction time: 5 min.

  • Pot life: 4 h.

  • Application methods: Airless spray, brush, roller.

  • Thinner: X-7 polyurethane thinner; dilution 3–7%.

  • Recoat interval (25°C): Min 12 h; max unlimited.

  • Recommended coats / DFT: 1 coat 40–60 μm; brush/roller 1 coat 30–40 μm.

Surface preparation
Steel: blast/shot blast to Sa 2.5 or power-tool cleaning to St 3; surface profile 30–75 μm.
Concrete: must be sound and dry (moisture content ≤6%), free of contamination; repair defects and apply after a sealing primer; for old coatings, roughen and remove chalked/loose parts.

System compatibility / packing / storage

  • Compatibility: S55-2 system—cooling tower damp-proof primer + topcoat.

  • Packing: Primer—Part A 24 kg, Part B 3 kg; topcoat—Part A 18 kg, Part B 3 kg.

  • Storage: Shelf life 12 months; store dry/cool/ventilated, away from fire and direct sunlight; no outdoor stacking.

Contact Us

We would love to speak with you.
Feel free to reach out using the below details.

HUILI fireproof coatings metal paint pail

Special Outdoor Non-Intumescent Fireproof Coating for Steel Structure – Special cementitious coating for hydrocarbon-flame fire protection.

  • For petrochemical/chemical outdoor steel structures.

  • 3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.

  • Air spray 0.6–0.8 MPa; nozzle Φ4.0–6.0 mm.

HUILI fireproof coatings metal paint pail

Outdoor Non-Intumescent Fireproof Coating for Steel Structure – Outdoor non-intumescent fireproof coating for steel structures.

  • 3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.

  • Bond strength test result: 0.11 MPa.

  • Fire test: 33 mm thickness; 5400 mm span; 3.00 h.

HUILI anti-corrosion coatings metal paint pail

Inorganic Zinc-Rich Primer (2K) – Two-component ethyl silicate zinc-rich primer for cathodic protection of blast-cleaned steel.

  • General-purpose use for bridges, towers, gas holders, oil tanks, oil/gas pipelines, and industrial steel structures.

  • High zinc dust content with stated water/oil/media resistance and welding/cutting resistance.

  • Sa 3 surface preparation (not lower than Sa 2.5); touch dry 10 min at 25°C, RH 70–85%.

HUILI anti-corrosion coatings metal paint pail

Epoxy Zinc Primer (2K, C6-Modified) – Two-component epoxy zinc primer (C6-modified) for cathodic-protection priming.

  • Salt spray resistance 1300 h (as stated).

  • Theoretical consumption 0.25 kg/m² at 50 µm DFT (losses not included).

  • For offshore platforms, underwater steel, pipelines, oil tanks, bridges, and petrochemical steel structures.

INQUIRY NOW