ISO 9001:2015 Certified

S55-2 Polyurethane cooling tower damp-proof coating (primer/topcoat)

2K polyurethane moisture-resistant coating with abrasion-resistant film, anti-mold performance and outstanding water resistance for cooling towers and underground concrete structures. Suited for wastewater pools and mine shafts. 30–35µm DFT, 120–150µm total system.

Facebook
Twitter
LinkedIn

S55-2 Polyurethane cooling tower damp-proof coating (primer/topcoat) Description

Overview
Two-component polyurethane damp-proof coating system for waterproofing and anti-corrosion.
Provides strong adhesion, water resistance, damp-heat resistance, corrosion resistance, and mildew resistance.

Composition
Formulated with polyurethane resin, impermeability pigments, anti-rust pigments, reinforcing materials, solvents, and additives.
Cured with polyisocyanate; supplied in Part A & Part B packs.

Typical uses
Waterproof and anti-corrosion for concrete structures and steel structures, including cooling towers, sewage tanks, mines, and underground buildings.

Technical data (typical)

  • Appearance: Primer—brown; topcoat—grey.

  • Theoretical consumption: Primer 0.16 kg/m² at 50 μm DFT; topcoat 0.13 kg/m² at 40 μm DFT (excluding loss).

  • Density: Primer 1.4 kg/L; topcoat 1.2 kg/L.

  • Drying time (25°C): Surface dry 1 h; hard dry 24 h; fully cured 7 d.

Application data (25°C)

  • Mixing ratio (Part A:Part B): Primer 24:3; topcoat 18:3.

  • Induction time: 5 min.

  • Pot life: 4 h.

  • Application methods: Airless spray, brush, roller.

  • Thinner: X-7 polyurethane thinner; dilution 3–7%.

  • Recoat interval (25°C): Min 12 h; max unlimited.

  • Recommended coats / DFT: 1 coat 40–60 μm; brush/roller 1 coat 30–40 μm.

Surface preparation
Steel: blast/shot blast to Sa 2.5 or power-tool cleaning to St 3; surface profile 30–75 μm.
Concrete: must be sound and dry (moisture content ≤6%), free of contamination; repair defects and apply after a sealing primer; for old coatings, roughen and remove chalked/loose parts.

System compatibility / packing / storage

  • Compatibility: S55-2 system—cooling tower damp-proof primer + topcoat.

  • Packing: Primer—Part A 24 kg, Part B 3 kg; topcoat—Part A 18 kg, Part B 3 kg.

  • Storage: Shelf life 12 months; store dry/cool/ventilated, away from fire and direct sunlight; no outdoor stacking.

Contact Us

We would love to speak with you.
Feel free to reach out using the below details.

HUILI fireproof coatings metal paint pail

GT-WSF-Fp3.00 Outdoor Non-Intumescent Fireproof Coating for Steel Structure

Cementitious non-intumescent fire-resistant coating with 3-hour fire rating and weather resistance for outdoor steel structures. Suited for stations, ports, warehouses and stadiums in aggressive environments. Sa2.5 prep, 16–33mm total application thickness.

HUILI fireproof coatings metal paint pail

GT-WSP-Fp2.00 Outdoor Intumescent Fireproof Coating for Steel Structure

Single-component water-based intumescent coating with 2-hour fire rating and outstanding weathering resistance for exterior steel structures. Resistant to UV, salt spray, freeze-thaw and acid-alkali exposure. Sa2.5 prep, 1.7–3.2mm application thickness.

HUILI anti-corrosion coatings metal paint pail

PLH06-1 Epoxy Zinc-Rich Primer

2K epoxy zinc-rich primer engineered for cathodic protection on structural steel. Suited for shipbuilding, bridges & oil tanks in aggressive environments. Sa2.5 prep required, 35–40µm DFT.

INQUIRY NOW

Contact Information