Cyanate waterproof coating for cooling tower linings and building damp-proofing.
Cooling towers, sewage tanks, basements.
Single-component; recoat 12 h–7 d.
Strong adhesion; anti-permeation; anti-mildew.
Overview
Single-component cyanate waterproof coating for waterproofing and damp-proofing on building structures.
Composition
Cyanate prepolymer, adhesion promoter, pigments, sealing additive, solvent, catalyst.
Typical uses
Waterproofing and damp-proofing for cooling tower internal walls, sewage tanks, and basements.
Can be used in systems with epoxy and polyurethane coatings.
Technical data (typical)
Appearance: brown.
Theoretical consumption: 0.16 kg/m² at 50 µm DFT (loss not included).
Density: topcoat 1.27 kg/L.
Drying time (25°C): surface dry 1 h; hard dry 24 h; full cure 7 d.
Application data (25°C)
Mixing: single-component.
Induction time: none.
Pot life: unlimited.
Application methods: airless spray, brush, roller.
Thinner: cyanate thinner, 3–7%.
Recoat interval: min 12 h; max 7 d.
Recommended DFT per coat: 40–60 µm (brush/roller 30–40 µm).
Surface preparation
Steel: blast to Sa 2.5 or power-tool clean to St 3; surface profile 30–75 µm.
Concrete: sound and dry; moisture content ≤6%; clean and free of oil/dirt; repair defects before coating.
System compatibility / packing / storage
System compatibility: cyanate waterproof primer + cyanate waterproof topcoat.
Packing: 25 kg.
Storage: dry, cool, ventilated; away from fire; avoid strong sunlight; no outdoor storage.
Shelf life: 12 months.
We would love to speak with you.
Feel free to reach out using the below details.
Epoxy High-Build Topcoat (2K) – High-solids epoxy topcoat for heavy-duty protection.
For steel structures and concrete surfaces.
Induction time 5 h; pot life 3 h.
Recoat 24 h–7 d; X-7 thinner 3–9%.
Outdoor Non-Intumescent Fireproof Coating for Steel Structure – Outdoor non-intumescent fireproof coating for steel structures.
3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.
Bond strength test result: 0.11 MPa.
Fire test: 33 mm thickness; 5400 mm span; 3.00 h.
Modified Epoxy Iron Oxide Red Primer (2K) – Two-component modified epoxy iron oxide red anti-rust primer for steel and concrete.
For corrosion protection of steel structures and concrete surfaces.
Water and corrosion resistance with strong adhesion (as described).
Mix ratio 24:3; recoat 24 h–7 d (25°C).
Epoxy Zinc Primer (2K, C6-Modified) – Two-component epoxy zinc primer (C6-modified) for cathodic-protection priming.
Salt spray resistance 1300 h (as stated).
Theoretical consumption 0.25 kg/m² at 50 µm DFT (losses not included).
For offshore platforms, underwater steel, pipelines, oil tanks, bridges, and petrochemical steel structures.
Protect. Perform. Endure. – Advanced Coatings for Industrial Excellence.
© 2025 All Rights reserved Anhui HUILI Coating Technology Co., Ltd. | Privacy Policy