Surface Preparation for Industrial Coatings: ISO 8501, SSPC & Practical Selection Guide
Surface Preparation for I
Premium acrylic marking coating for chimney and steel tower marking.
For power plant concrete chimneys and steel towers.
Single-component; min recoat 12 h at 25°C.
Thinner X-14; dilution 3–7%.
Overview
Single-component premium acrylic marking coating with outstanding weathering resistance.
Designed for heat resistance, cold resistance, gloss retention, and color retention; fast drying and suitable for low-temperature application.
Composition
Formulated with premium acrylic resin, quality pigments, plasticizer, solvents, and additives.
Typical uses
For marking and protection on concrete-structure chimneys in power plants, and for marking/protection on steel towers.
Technical data (typical)
Appearance: White; bright red, etc.
Theoretical consumption: 0.14 kg/m² at 35 μm DFT (excluding loss).
Density: 1.2 kg/L.
Drying time (25°C): Surface dry 1 h; hard dry 10 h.
Gloss: ≥80.
Application data (25°C)
Mixing: Single-component.
Induction time: None.
Pot life: Unlimited.
Application methods: Airless spray, brush, roller.
Thinner: X-14 acrylic thinner; dilution 3–7%.
Recoat interval (25°C): Min 12 h; max unlimited.
Recommended coats / DFT: 1 coat 40–50 μm; brush/roller 1 coat 30–40 μm.
Surface preparation
Steel: blast/shot blast to Sa 2.5 or power-tool cleaning to St 3; surface profile 30–75 μm.
Concrete: must be dry (moisture content ≤6%), free of oil/contamination; apply after a sealing primer; for old coatings, consider roughening and remove chalked/loose areas.
System compatibility / packing / storage
Packing: 20 kg.
Storage: Shelf life 12 months; store dry/cool/ventilated, away from fire and direct sunlight; no outdoor stacking.
CSPE cooling tower damp-proof coating for inner wall anti-corrosion service.
For cooling tower inner wall protection.
Single-component; min recoat 12 h at 25°C.
Resists freeze-thaw, damp heat, and mildew.
Polyurethane cooling tower damp-proof coating (2K) for waterproof anti-corrosion lining.
For cooling towers, sewage tanks, mines, underground buildings.
Primer ratio 24:3; topcoat ratio 18:3.
Pot life 4 h; min recoat 12 h.
Premium polyurethane marking coating (2K) for steel structures and concrete chimneys.
For chimney marking and protection.
Mixing ratio 18:3; pot life 4 h.
High gloss; fully hardened 7 d at 25°C.
Epoxy bitumen cooling tower damp-proof coating (2K) for cooling tower inner wall protection.
For cooling towers, sewage tanks, underground mines.
Mixing ratio 25:2.5; pot life 4 h.
Waterproof, anti-seepage, and mildew resistant.