Surface Preparation for Industrial Coatings: ISO 8501, SSPC & Practical Selection Guide
Surface Preparation for I
Polyurethane MIO intermediate coating (2K) for sealing and reinforcement in PU systems.
Intermediate layer for polyurethane coating systems.
Mixing ratio 9:1; thinner X-10 at 3–7%.
Compatible with polyurethane and acrylic polyurethane topcoats.
Overview
Two-component micaceous iron oxide anti-rust coating / intermediate coating with shielding effect and anti-corrosion performance.
Designed for good intercoat adhesion with primers and topcoats; fast drying and low-temperature applicability.
Composition
Based on polyurethane resin, micaceous iron oxide (MIO) powder, quality pigments, solvents, and additives.
Cured with polyisocyanate; supplied in Part A & Part B packs.
Typical uses
Intermediate coating for polyurethane coating systems to improve sealing and build.
Can also be used as the first coat primer.
Technical data (typical)
Appearance: Grey; brown.
Theoretical consumption: 0.14 kg/m² at 50 μm DFT (excluding loss).
Density: 1.45 kg/L.
Drying time (25°C): Surface dry 2 h; hard dry 24 h; fully cured 7 d.
Application data (25°C)
Mixing ratio (Part A:Part B): 9:1.
Induction time: 5 min.
Pot life: 3 h.
Application methods: Airless spray, brush, roller.
Thinner: X-10 polyurethane thinner; dilution 3–7%.
Recoat interval (25°C): Min 24 h; max 7 d.
Recommended coats / DFT: 1 coat 40–70 μm; brush/roller 1 coat 30–40 μm.
Surface preparation
Remove dust, oil, and debris from the previous coat; if beyond maximum recoat interval, roughen the surface.
When used as the first coat: blast/shot blast to Sa 2.5 or power-tool cleaning to St 3; surface profile 30–75 μm.
System compatibility / packing / storage
Compatibility: Polyurethane topcoat; acrylic polyurethane topcoat.
Packing: Part A 27 kg; Part B 3 kg.
Storage: Shelf life 12 months; store dry/cool/ventilated, away from fire and direct sunlight; no outdoor stacking.
CSPE cooling tower damp-proof coating for inner wall anti-corrosion service.
For cooling tower inner wall protection.
Single-component; min recoat 12 h at 25°C.
Resists freeze-thaw, damp heat, and mildew.
Polyurethane cooling tower damp-proof coating (2K) for waterproof anti-corrosion lining.
For cooling towers, sewage tanks, mines, underground buildings.
Primer ratio 24:3; topcoat ratio 18:3.
Pot life 4 h; min recoat 12 h.
Premium polyurethane marking coating (2K) for steel structures and concrete chimneys.
For chimney marking and protection.
Mixing ratio 18:3; pot life 4 h.
High gloss; fully hardened 7 d at 25°C.
Epoxy bitumen cooling tower damp-proof coating (2K) for cooling tower inner wall protection.
For cooling towers, sewage tanks, underground mines.
Mixing ratio 25:2.5; pot life 4 h.
Waterproof, anti-seepage, and mildew resistant.