Surface Preparation for Industrial Coatings: ISO 8501, SSPC & Practical Selection Guide
Surface Preparation for I
Winter-grade epoxy coal tar bitumen coating (2K) that can be applied at -5°C.
Buried pipelines; steel and concrete protection.
Mix ratio 20:4; recoat 12 h–7 d.
Seawater, oil, chemical resistance; high insulation.
Overview
Two-component winter-grade epoxy coal tar bitumen coating designed to cure under low-temperature conditions.
Composition
Epoxy resin, coal tar pitch, anti-rust pigments, solvent, additives, catalyst; fast-drying curing agent; supplied as Part A & Part B.
Typical uses
Corrosion protection for steel and concrete in severe corrosive environments.
Suitable for external anti-corrosion of buried pipelines.
Technical data (typical)
Appearance: primer brown-black; topcoat black.
Theoretical consumption: 0.18 kg/m² at 60 µm DFT (loss not included).
Density: 1.32 kg/L.
Volume solids: ≥75%.
Drying time (25°C): surface dry 1 h; hard dry 24 h; full cure 7 d.
Application data (25°C)
Mixing ratio (A:B): 20:4.
Induction time: 5 min.
Pot life: 4 h.
Application methods: spray, brush, roller.
Thinner: HL52-6 dedicated thinner, 3–8%.
Recoat interval (25°C): min 12 h; max 7 d.
Recommended DFT per coat: 40–70 µm (brush/roller 30–40 µm).
Surface preparation
Blast to Sa 2.5 or power-tool clean to St 3; surface profile 30–75 µm.
System compatibility / packing / storage
System compatibility: winter-grade epoxy coal tar bitumen primer + winter-grade epoxy coal tar bitumen topcoat.
Packing: Part A 20 kg; Part B 4 kg.
Storage: store in a dry, cool, ventilated place; keep away from fire; avoid strong sunlight; no outdoor storage.
Shelf life: 12 months.
CSPE cooling tower damp-proof coating for inner wall anti-corrosion service.
For cooling tower inner wall protection.
Single-component; min recoat 12 h at 25°C.
Resists freeze-thaw, damp heat, and mildew.
Polyurethane cooling tower damp-proof coating (2K) for waterproof anti-corrosion lining.
For cooling towers, sewage tanks, mines, underground buildings.
Primer ratio 24:3; topcoat ratio 18:3.
Pot life 4 h; min recoat 12 h.
Premium polyurethane marking coating (2K) for steel structures and concrete chimneys.
For chimney marking and protection.
Mixing ratio 18:3; pot life 4 h.
High gloss; fully hardened 7 d at 25°C.
Epoxy bitumen cooling tower damp-proof coating (2K) for cooling tower inner wall protection.
For cooling towers, sewage tanks, underground mines.
Mixing ratio 25:2.5; pot life 4 h.
Waterproof, anti-seepage, and mildew resistant.