
Surface Preparation for Industrial Coatings: ISO 8501, SSPC & Practical Selection Guide
Surface Preparation for I
Indoor Non-Intumescent Fireproof Coating for Steel Structure – Indoor cementitious thermal-insulation fireproof coating for steel.
3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.
Air spray 0.6–0.8 MPa; nozzle Φ4.0–6.0 mm.
Fire test: 32 mm thickness; 5400 mm span; 3.00 h.
Overview
Indoor non-intumescent fireproof coating for steel structures, formulated to form a fire-resistant thermal insulation protective layer and reduce fire damage to load-bearing steel structures.
The document states it does not corrode steel, does not chemically react with anti-corrosion primers, has no irritating odor, produces no smoke during fire exposure, and does not release harmful gases.
The document states the product performance meets or exceeds GB 14907-2018 (Steel Structure Fireproof Coatings).
Composition
Lightweight thermal insulation materials, refractory cement, and inorganic hydraulic materials.
Typical uses
The document lists stations, docks, warehouses, stadiums, exhibition centers, and office buildings (application text in the file).
Technical data (typical)
Color: Gray.
Gloss: Matt (no gloss).
Density / specific gravity: 0.4 kg/L.
Shelf life: 12 months (shown in the physical data table).
Packaging: 20 kg/bag.
Coating theoretical (fire resistance requirement → thickness → number of coats → theoretical consumption): 3 h → ≥33 mm → 5–6 coats → 20–22 kg/m²; 2 h → ≥24 mm → 3–4 coats → 15–17 kg/m²; 1 h → ≥16 mm → 2–3 coats → 10–12 kg/m².
Key test results (as listed): bond strength 0.11 (MPa not explicitly shown in the result cell); heat/cold cycling (15 cycles) insulation efficiency attenuation 3%; fire test: measured thickness 32 mm, steel beam span 5400 mm, test time 3.00 h, max deflection 29.80 mm, average temperature 523.98°C.
Application data (25°C)
Thinner: Water.
Application methods: Air spray and trowel application are stated.
Spray equipment (as listed): continuous air supply pressure 0.6–0.8 MPa; spray gun nozzle diameter Φ4.0–6.0 mm.
Mixing ratio: coating : water : binder is referenced for spray and trowel application (numeric values are not shown in the provided table cells).
Wet mix usable time (as stated): wet material must be used within 2 h (given in the interface layer / trowel mixing notes).
Trowel application control (as stated): each pass thickness 6–8 mm; interval about 24 h between passes; keep the surface rough between layers to improve bonding.
Curing/conditioning (as stated): after reaching design thickness and final set, keep moist curing for 7 days (water spray suggested); for fire performance testing, natural curing ≥35 days at 5–35°C.
Surface preparation
Prior to blasting: grind welds, remove welding spatter and burrs, and round sharp edges.
Blast cleaning to Sa 2.5, or power-tool cleaning to St 3 to ensure steel is fully exposed and free of mill scale/oxide scale.
Apply coating within 5 h after surface preparation (as stated).
Apply at least two coats of anti-corrosion primer first; apply the fireproof coating after the anti-corrosion primer is dry.
System compatibility / packing / storage
The document states no chemical reaction with anti-corrosion primers.
After the coating is thoroughly dry, two coats of decorative topcoat (tintable) may be applied to improve service life and appearance (as stated).
Storage: sealed, stored off the ground in a ventilated and dry place without direct sunlight; prevent moisture and rain ingress; storage temperature 5–35°C.
Shelf life: 9 months (stated in the storage section).
Packaging: 20 kg/bag.
CSPE cooling tower damp-proof coating for inner wall anti-corrosion service.
For cooling tower inner wall protection.
Single-component; min recoat 12 h at 25°C.
Resists freeze-thaw, damp heat, and mildew.
Polyurethane cooling tower damp-proof coating (2K) for waterproof anti-corrosion lining.
For cooling towers, sewage tanks, mines, underground buildings.
Primer ratio 24:3; topcoat ratio 18:3.
Pot life 4 h; min recoat 12 h.
Premium polyurethane marking coating (2K) for steel structures and concrete chimneys.
For chimney marking and protection.
Mixing ratio 18:3; pot life 4 h.
High gloss; fully hardened 7 d at 25°C.
Epoxy bitumen cooling tower damp-proof coating (2K) for cooling tower inner wall protection.
For cooling towers, sewage tanks, underground mines.
Mixing ratio 25:2.5; pot life 4 h.
Waterproof, anti-seepage, and mildew resistant.

Surface Preparation for I

Industrial Coating Failur

Anti Corrosion Coating Mi
We would love to speak with you.
Feel free to reach out using the below details.