Chlorosulfonated polyethylene gas holder dedicated coating for gas holder outer wall protection.
For gas holders; also for other steel structures.
Single-component; min recoat 24 h at 25°C.
Resists water, H₂S, and chemical gas corrosion.
Overview
Single-component chlorosulfonated polyethylene gas holder dedicated coating for external wall protection.
Provides resistance to water, hydrogen sulfide, and chemical gas corrosion; fast drying and suitable for low-temperature application.
Composition
Formulated with chlorosulfonated polyethylene resin, modified resin, quality pigments, mixed solvents, and multiple additives.
Typical uses
Protection of gas holder outer walls; also suitable for anti-corrosion of other steel structures.
Technical data (typical)
Appearance: Primer—red iron oxide, grey; intermediate—red-brown; topcoat—various colors.
Theoretical consumption: Primer 0.17 kg/m² at 60 μm DFT; intermediate 0.17 kg/m² at 40 μm DFT; topcoat 0.2 kg/m² at 50 μm DFT (excluding loss).
Density: Primer 1.37 kg/L; intermediate 1.4 kg/L; topcoat 1.2 kg/L.
Drying time (25°C): Surface dry 1 h; hard dry 24 h.
Application data (25°C)
Mixing: Single-component.
Induction time: None.
Pot life: Unlimited.
Application methods: Airless spray, brush, roller.
Thinner: X-1 chlorosulfonated polyethylene thinner; dilution 3–7%.
Recoat interval (25°C): Min 24 h; max unlimited.
Recommended coats / DFT: 1 coat 40–60 μm; brush/roller 1 coat 30–40 μm.
Surface preparation
Steel: blast/shot blast to Sa 2.5, or power-tool cleaning to St 3.
Surface profile: 30–75 μm.
System compatibility / packing / storage
Compatibility: PLJ52-4 dedicated system—primer + intermediate + topcoat.
Packing: Primer and intermediate 25 kg; topcoat 22 kg.
Storage: Shelf life 12 months; store dry/cool/ventilated, away from fire and direct sunlight; no outdoor stacking.
We would love to speak with you.
Feel free to reach out using the below details.
Outdoor Non-Intumescent Fireproof Coating for Steel Structure – Outdoor non-intumescent fireproof coating for steel structures.
3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.
Bond strength test result: 0.11 MPa.
Fire test: 33 mm thickness; 5400 mm span; 3.00 h.
Outdoor Intumescent Fireproof Coating for Steel Structure – Waterborne intumescent coating for outdoor steel fire protection.
2 h rating: ≥3.2 mm; 4.5 kg/m² theoretical consumption.
Air spray 0.6–0.8 MPa; nozzle Φ4.0–6.0 mm.
Bond strength test result: 0.77 MPa.
Inorganic Zinc Silicate Primer (2K) – Two-component inorganic zinc silicate primer for long-term steel corrosion protection with cathodic protection.
For blast-cleaned steel; surface preparation Sa 3 (not lower than Sa 2.5) is specified.
Fast drying at 25°C, RH 70–85%: touch dry 10 min; hard dry 2 h; cured 24 h.
Mix ratio 28:7; thinner X-11 inorganic zinc thinner (5–20%); compatible with epoxy/PU coating systems.
Epoxy MIO Intermediate Coating (2K) – Two-component epoxy micaceous iron oxide intermediate coating for barrier protection.
For ships, containers, bridges, steel gates, gas holders, port machinery, and steel structures; used over zinc-rich primer or sprayed zinc.
Mix ratio 27:3; pot life 4 h (25°C).
Recoat 12 h–7 d (25°C); overcoatable with epoxy and polyurethane systems.
Protect. Perform. Endure. – Advanced Coatings for Industrial Excellence.
© 2025 All Rights reserved Anhui HUILI Coating Technology Co., Ltd. | Privacy Policy