ISO 9001:2015 Certified

Aviation Marking Coatings

4 aviation marking coatings for steel and concrete chimneys, transmission towers and tall structures requiring civil aviation obstacle marking — polyurethane, acrylic-silicone, thermoplastic acrylic and CR-acrylic formulations in aviation white and aviation red, with ≥10-year service life and low-temperature application capability.

4

Products

120μm

Max DFT Single Coat

10+ yr

Service Life (PLB83-1)

SUB-CATEGORIES
2-Pack Polyurethane Marking
1 product
Acrylic-Silicone Long-Life Marking
1 product
Thermoplastic Acrylic Marking
1 product
CR-Acrylic Marking
1 product
Product Catalogue

Aviation Marking Coatings for Chimneys, Towers & Tall Structures

Polyurethane, acrylic-silicone, thermoplastic acrylic and CR-acrylic aviation marking coatings in aviation white and aviation red — all specified at ≥4 coats to ≥120 μm DFT for civil aviation obstacle marking compliance on steel and concrete structures.

Aviation Marking Coatings (4)
HUILI anti-rust coatings metal paint pail

PLS86-4 Premium polyurethane marking coating

2K polyurethane marking coating with high-gloss, UV resistance and freeze-thaw resistance for steel and concrete chimneys and transmission towers. Anti-chalking and anti-yellowing performance. 30µm DFT per coat, 4-coat system to 120µm.

HUILI anti-rust coatings metal paint pail

PLJB82-81 Chlorinated rubber acrylic marking coating

Single-component chlorinated rubber acrylic marking coating with excellent weathering, seawater and chemical atmosphere resistance for chimneys and steel towers. Fast-drying with low-temperature cure capability. 30µm DFT per coat, 120µm+ system.

HUILI anti-rust coatings metal paint pail

PLB86-2 Premium acrylic marking coating

Single-component acrylic marking coating with outstanding UV resistance, color retention and heat and cold resistance for chimneys and steel towers. Fast-drying with low-temperature cure capability. 35µm DFT per coat, 120µm+ system.

HUILI anti-rust coatings metal paint pail

PLB83-1 High-performance long-lasting special marking coating

Single-component acrylic silicone marking coating with 10+ year service life and outstanding UV and heat resistance for steel and concrete chimneys. Suited for transmission towers in all natural environments. 30µm DFT per coat, 120µm+ system.

About Aviation Marking Coatings

Civil aviation regulations require tall structures — chimneys, transmission towers, wind turbine towers and other elevated obstacles — to carry high-visibility aviation obstacle markings in aviation white and aviation red. These coatings must maintain vivid, stable colour under years of continuous UV exposure, extreme temperature cycling, rain and industrial atmospheric pollution without fading, chalking or peeling. All four products in this series are specified at ≥4 coats to ≥120 μm DFT and are suitable for both steel and concrete substrates.

The series offers four chemistry options to match project requirements: PLS86-4 two-pack polyurethane for maximum hardness, gloss and anti-yellowing performance; PLB83-1 acrylic-silicone for the longest rated service life (10+ years); PLB86-2 thermoplastic acrylic for fast dry, cost-effective marking on standard structures; and PLJB82-81 CR-acrylic for enhanced chemical atmosphere and marine climate resistance where industrial gas exposure is a factor. All products are compatible with galvanised steel when a suitable sealer primer is applied first.

Technical Specifications

Technical Data: All 4 Aviation Marking Coating Products

All products specified at ≥4 coats to ≥120 μm DFT. Substrate moisture ≤6% required; galvanised steel needs sealer primer before application.

 
CodeProductDFT / coatPackThinnerSurface DryMin RecoatKey Feature
PLS86-4Premium PU Marking Paint30 μm2-pack 10:1X-10 ≤5%24 h4 hHighest hardness & gloss, anti-yellowing
PLB83-1Long-Life Acrylic-Silicone Marking30 μmSingle-packPLB83 5–8%1 h4 h10+ year service life, any climate
PLB86-2Acrylic Marking Paint35 μmSingle-packX-14 5–8%1 h4 hFast dry, power plant chimneys
PLJB82-81CR-Acrylic Marking Paint30 μmSingle-packSpecialist 5–8%1 h4 hChemical atmosphere & marine climate
End-Use Markets

Aviation Marking Coatings — Where They Are Specified

Structure type and atmospheric environment determine product selection — all four products meet the ≥120 μm DFT aviation marking specification requirement.

Steel & Concrete Chimneys

Industrial chimneys at power stations, cement plants and chemical facilities are among the most demanding environments for aviation marking coatings — combining high-temperature flue gas radiation from the stack surface, acid gas fallout and continuous UV exposure. PLB83-1 acrylic-silicone with its 10+ year rated service life is the primary specification for chimney marking where maintenance access is difficult and repainting intervals must be maximised. PLS86-4 two-pack polyurethane is preferred where the highest gloss and anti-yellowing performance is required.

High-Voltage Transmission Towers

Transmission towers in remote and rural locations must carry aviation markings for extended periods with minimal maintenance access. The 10+ year service life of PLB83-1 acrylic-silicone makes it the preferred specification for transmission tower marking where repainting frequency must be minimised. PLJB82-81 CR-acrylic is specified for towers in coastal or industrial locations where chemical atmosphere and marine climate resistance are additionally required.

Power Plant Structures — Chemical & Industrial Atmosphere

Power plant chimneys and structures in industrial zones face combined UV, acid gas and chemical atmosphere exposure. PLJB82-81 CR-acrylic marking paint provides enhanced resistance to chemical atmospheres and marine climates while maintaining the vivid aviation red and white colouration required by civil aviation regulations. PLB86-2 thermoplastic acrylic is the cost-effective option for standard power plant chimney marking in moderate atmospheric conditions.

Galvanised Steel Structures

All four aviation marking products in this series are suitable for application on galvanised steel structures — but require application of a specialist sealer primer over the galvanised surface before the marking coat system is applied. This ensures adequate inter-coat adhesion between the zinc surface and the marking paint film. Substrate moisture must be ≤6% for all products regardless of substrate type. Contact our technical team for sealer primer recommendations compatible with each marking paint system.

Get a Quote

Request a Technical Recommendation

Tell us your substrate, environment and project scale — our technical team will recommend the right system and provide a quotation within 24 hours.

Email Us: info@huilicoating.com
Technical Support: +86 123 4567 890

INQUIRY NOW

Contact Information