Waterborne alkyd general-purpose coating for indoor/outdoor metal and wood.
General metalwork and wood components.
0.15 kg/m² at 50 µm; recoat ≥24 h.
Water thinning ≤10%; optional 90℃ oven dry.
Overview
Waterborne alkyd general-purpose coating for interior and exterior metal and wood where basic corrosion protection and decorative hardness are required.
Film emphasizes hardness and adhesion with balanced mechanical properties and system compatibility for primer/topcoat use.
Composition
Waterborne alkyd resin as main binder with pigments, fillers, and special additives; single-component waterborne system using water as thinner.
Typical uses
General protective and decorative coating for indoor and outdoor metal and wood components, providing basic corrosion protection and appearance.
Technical data (typical)
Appearance: various colors.
Density: 1.25 kg/L.
Theoretical consumption: 0.15 kg/m² at 50 µm DFT (loss not included).
Drying time (25℃): surface dry 2 h; hard dry 24 h; full cure 7 d.
Forced drying (optional): flash-off 15 min, 90℃ for 15 min.
Application data (25°C)
Application methods: spray, brush, roller.
Thinner: pure water, ≤10%.
Recoat interval: ≥24 h.
Surface preparation
Steel: blast or power-tool clean to Sa 2.5 or St 3 with 30–75 µm profile before coating.
System compatibility / packing / storage
System compatibility: can be used in compatible waterborne alkyd systems on metal and wood substrates.
Storage: dry, cool, ventilated warehouse; 5–35℃; avoid strong sunlight, severe cold, and rain; keep containers sealed.
Shelf life: 6 months.
We would love to speak with you.
Feel free to reach out using the below details.
Epoxy High-Build Topcoat (2K) – High-solids epoxy topcoat for heavy-duty protection.
For steel structures and concrete surfaces.
Induction time 5 h; pot life 3 h.
Recoat 24 h–7 d; X-7 thinner 3–9%.
Outdoor Intumescent Fireproof Coating for Steel Structure – Waterborne intumescent coating for outdoor steel fire protection.
2 h rating: ≥3.2 mm; 4.5 kg/m² theoretical consumption.
Air spray 0.6–0.8 MPa; nozzle Φ4.0–6.0 mm.
Bond strength test result: 0.77 MPa.
Epoxy Sealer Primer (2K) – Two-component penetrating sealer primer for porous substrates.
For cement mortar, concrete, and fiber cement boards; also stated for wood.
Concrete moisture content < 6% before application (as stated).
Mix ratio 16:4; theoretical consumption 0.29 kg/m² at 50 µm DFT.
Epoxy Glass Flake Intermediate Coating (2K) – Two-component epoxy glass flake intermediate coating for heavy-duty barrier protection.
For marine/offshore, chemical areas, underground mines, and wastewater facilities; steel and concrete substrates.
Mix ratio 25:2.5; pot life 4 h (25°C).
Recoat 24 h–7 d (25°C); recommended DFT 60–80 µm per coat.
Protect. Perform. Endure. – Advanced Coatings for Industrial Excellence.
© 2025 All Rights reserved Anhui HUILI Coating Technology Co., Ltd. | Privacy Policy