Waterborne rust conversion primer for converting rust into a stable protective layer.
Tanks, bridges, pipelines, brackets, auto parts.
0.1 kg/m² at 40 µm; 1–2 coats.
Second coat within 10 min; overcoat after 24 h.
Overview
Waterborne rust conversion primer that chemically converts rust into part of the coating film.
Composition
Special copolymer emulsion with functional additives and rust converter; water as thinner; fully dry film is blue-purple or black.
Typical uses
Rust-conversion pretreatment for rusted metal substrates of tanks, bridges, pipelines, brackets, automotive parts, etc., forming an integral anti-rust coating by reacting with rust.
Technical data (typical)
Appearance: milky white or brown uniform liquid.
Density: 1.05 kg/L.
Theoretical consumption: 0.1 kg/m² at 40 µm DFT (loss not included).
Drying time (25°C): surface dry 30 min; hard dry 24 h.
Application data (25°C)
Application methods: spray, brush, roller.
Thinner: clean water, ≤5%.
Number of coats: 1–2 depending on rust level.
Recoat rules: if a second rust-conversion coat is needed, apply within 10 min after first coat; after completion, minimum 24 h before applying subsequent intermediate or topcoats.
Surface preparation
Use water jet, wire brush, or power tools to remove loose rust, oil, and other non-adherent matter; minimum St1–St2.
System compatibility / packing / storage
Construction conditions: ambient 5–35°C; not suitable in rain, fog, snow, or when RH ≥85%.
Storage: dry, cool, ventilated; temperature 5–35°C; avoid strong sunlight, severe cold, and rain.
Shelf life: 12 months.
We would love to speak with you.
Feel free to reach out using the below details.
Outdoor Non-Intumescent Fireproof Coating for Steel Structure – Outdoor non-intumescent fireproof coating for steel structures.
3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.
Bond strength test result: 0.11 MPa.
Fire test: 33 mm thickness; 5400 mm span; 3.00 h.
Indoor Intumescent Fireproof Coating for Steel Structure – Waterborne intumescent coating for indoor steel fire protection.
2 h rating: ≥3.3 mm; 4.6 kg/m² theoretical consumption.
Water-thinnable; max dilution 5%.
Bond strength test result: 0.82 MPa.
Inorganic Zinc-Rich Primer (2K) – Two-component ethyl silicate zinc-rich primer for cathodic protection of blast-cleaned steel.
General-purpose use for bridges, towers, gas holders, oil tanks, oil/gas pipelines, and industrial steel structures.
High zinc dust content with stated water/oil/media resistance and welding/cutting resistance.
Sa 3 surface preparation (not lower than Sa 2.5); touch dry 10 min at 25°C, RH 70–85%.
Epoxy Iron Oxide Red Anti-Rust Primer (2K) – Two-component epoxy anti-rust primer for steel structures.
For general steel structure corrosion protection; can be used for concrete with an epoxy sealer primer.
Mix ratio 24:3; pot life 4 h (25°C).
Recoat 24 h–7 d (25°C); overcoatable with epoxy and polyurethane systems.
Protect. Perform. Endure. – Advanced Coatings for Industrial Excellence.
© 2025 All Rights reserved Anhui HUILI Coating Technology Co., Ltd. | Privacy Policy