Surface Preparation for Industrial Coatings: ISO 8501, SSPC & Practical Selection Guide
Surface Preparation for I
Epoxy bitumen cooling tower damp-proof coating (2K) for cooling tower inner wall protection.
For cooling towers, sewage tanks, underground mines.
Mixing ratio 25:2.5; pot life 4 h.
Waterproof, anti-seepage, and mildew resistant.
Overview
Two-component epoxy bitumen damp-proof coating system for cooling tower inner walls.
Provides impermeability, waterproofing, mildew resistance, corrosion resistance, and heat resistance.
Composition
Formulated with epoxy resin, bitumen, lamellar fillers, solvents, and additives.
Cured with modified amine; supplied in Part A & Part B packs.
Typical uses
Protection of cooling tower inner walls, and waterproof/anti-corrosion for sewage tanks and underground mines.
Technical data (typical)
Appearance: Primer—red-brown; topcoat—black.
Theoretical consumption: 0.17 kg/m² at 60 μm DFT (excluding loss).
Density: 1.3 kg/L.
Drying time (25°C): Surface dry 1 h; hard dry 24 h; fully cured 7 d.
Application data (25°C)
Mixing ratio (Part A:Part B): 25:2.5.
Induction time: 5 min.
Pot life: 4 h.
Application methods: Airless spray, brush, roller.
Thinner: X-7 epoxy thinner; dilution 3–7%.
Recoat interval (25°C): Min 12 h; max unlimited.
Recommended coats / DFT: 1 coat 40–60 μm; brush/roller 1 coat 30–40 μm.
Surface preparation
Steel: blast/shot blast to Sa 2.5 or power-tool cleaning to St 3; surface profile 30–75 μm.
Concrete: must be sound and dry (moisture content ≤6%), free of contamination; repair defects and wash/de-alkalize, dry, then apply after a sealing primer.
System compatibility / packing / storage
Packing: Part A 25 kg; Part B 2.5 kg.
Storage: Shelf life 12 months; store dry/cool/ventilated, away from fire and direct sunlight; no outdoor stacking.
CSPE cooling tower damp-proof coating for inner wall anti-corrosion service.
For cooling tower inner wall protection.
Single-component; min recoat 12 h at 25°C.
Resists freeze-thaw, damp heat, and mildew.
Polyurethane cooling tower damp-proof coating (2K) for waterproof anti-corrosion lining.
For cooling towers, sewage tanks, mines, underground buildings.
Primer ratio 24:3; topcoat ratio 18:3.
Pot life 4 h; min recoat 12 h.
Premium polyurethane marking coating (2K) for steel structures and concrete chimneys.
For chimney marking and protection.
Mixing ratio 18:3; pot life 4 h.
High gloss; fully hardened 7 d at 25°C.
Epoxy bitumen cooling tower damp-proof coating (2K) for cooling tower inner wall protection.
For cooling towers, sewage tanks, underground mines.
Mixing ratio 25:2.5; pot life 4 h.
Waterproof, anti-seepage, and mildew resistant.

Surface Preparation for I

Industrial Coating Failur

Anti Corrosion Coating Mi
We would love to speak with you.
Feel free to reach out using the below details.