Surface Preparation for Industrial Coatings: ISO 8501, SSPC & Practical Selection Guide
Surface Preparation for I
Epoxy High-Build Topcoat (2K) – High-solids epoxy topcoat for heavy-duty protection.
For steel structures and concrete surfaces.
Induction time 5 h; pot life 3 h.
Recoat 24 h–7 d; X-7 thinner 3–9%.
Overview
Two-component epoxy high-build topcoat with high corrosion resistance and high solids, designed for thicker film build per coat.
It is described as having good chemical stability and resistance to oil, water, and solvents, plus electrical insulation properties.
Composition
Epoxy resin, weather-resistant pigments, additives, solvents, and polyamine compound curing agent; supplied as Part A & Part B.
Typical uses
Heavy-duty corrosion protection topcoat for steel structures and concrete surfaces.
Technical data (typical)
Appearance / color: Various colors.
Theoretical consumption: 0.2 kg/m² at 60 µm DFT (losses not included).
Density / specific gravity: 1.20 kg/L.
Drying / curing (25°C): Touch dry 2 h; hard dry 24 h; full cure 7 days.
Application data (25°C)
Mixing ratio (A:B): 20:4.
Induction time: 5 h.
Pot life: 3 h.
Application methods: Airless spray, brush, roller.
Thinner: X-7 epoxy thinner; dilution 3–9%.
Recoat interval: Minimum 24 h; maximum 7 days.
Recommended DFT: 50–80 µm per coat (brush/roller: 30–50 µm per coat).
Surface preparation
Over a two-component primer: surface must be clean, dry, and free of contaminants; abrade if maximum recoat interval is exceeded.
As first coat on steel: blast to Sa 2.5 or power-tool clean to St 3; surface profile 30–75 µm.
System compatibility / packing / storage
Compatible undercoats: inorganic zinc primer, epoxy zinc-rich primer, epoxy MIO intermediate coating, etc.
Shelf life: 12 months.
Storage: Store in a dry, cool, ventilated place away from ignition sources and direct sunlight; no outdoor storage.
Packaging: Part A 20 kg; Part B 4 kg.
CSPE cooling tower damp-proof coating for inner wall anti-corrosion service.
For cooling tower inner wall protection.
Single-component; min recoat 12 h at 25°C.
Resists freeze-thaw, damp heat, and mildew.
Polyurethane cooling tower damp-proof coating (2K) for waterproof anti-corrosion lining.
For cooling towers, sewage tanks, mines, underground buildings.
Primer ratio 24:3; topcoat ratio 18:3.
Pot life 4 h; min recoat 12 h.
Premium polyurethane marking coating (2K) for steel structures and concrete chimneys.
For chimney marking and protection.
Mixing ratio 18:3; pot life 4 h.
High gloss; fully hardened 7 d at 25°C.
Epoxy bitumen cooling tower damp-proof coating (2K) for cooling tower inner wall protection.
For cooling towers, sewage tanks, underground mines.
Mixing ratio 25:2.5; pot life 4 h.
Waterproof, anti-seepage, and mildew resistant.