Wet gas holder dedicated anti-corrosion coating (2K) for wet-type gas holder protection.
Dedicated for wet gas holders.
Pot life 3 h; recoat 24 h–7 d.
Primer/intermediate/topcoat system; H2S resistance.
Overview
Two-component anti-corrosion coating system (primer/intermediate/topcoat) dedicated for wet gas holders.
Composition
Modified special resin binder with anti-rust pigments, fillers, additives, and organic solvents; two-component product.
Typical uses
Dedicated protective coating for wet gas holders.
Technical data (typical)
Appearance: primer iron red or reddish brown; intermediate micaceous iron oxide red or micaceous iron oxide grey; topcoat various colors.
Theoretical consumption: primer 0.16 kg/m² at 50 µm DFT.
Theoretical consumption: intermediate 0.14 kg/m² at 50 µm DFT.
Theoretical consumption: topcoat 0.16 kg/m² at 50 µm DFT.
Density: primer 1.37 kg/L; intermediate 1.45 kg/L; topcoat 1.2 kg/L.
Drying time (25°C): surface dry 1 h; hard dry 24 h; full cure 7 d.
Application data (25°C)
Mixing ratio (A:B): primer 24:3; intermediate 27:3; topcoat 18:3.
Induction time: 5 min.
Pot life: 3 h.
Application methods: airless spray, brush, roller.
Thinner: X-1 dedicated thinner, 2–8%.
Recoat interval: min 24 h; max 7 d.
Recommended DFT per coat: 60–80 µm (brush/roller 35–45 µm).
System: PL wet gas holder dedicated primer + intermediate + topcoat.
Surface preparation
Steel: blast to Sa 2.5 or power-tool clean to St 3; surface profile 30–75 µm.
System compatibility / packing / storage
System compatibility: PL wet gas holder dedicated primer + intermediate + topcoat.
Packing: primer Part A 24 kg, Part B 3 kg; intermediate Part A 27 kg, Part B 3 kg; topcoat Part A 18 kg, Part B 3 kg.
Storage: dry, cool, ventilated; away from fire; avoid strong sunlight; no outdoor storage.
Shelf life: 12 months.
We would love to speak with you.
Feel free to reach out using the below details.
Indoor Non-Intumescent Fireproof Coating for Steel Structure – Indoor cementitious thermal-insulation fireproof coating for steel.
3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.
Air spray 0.6–0.8 MPa; nozzle Φ4.0–6.0 mm.
Fire test: 32 mm thickness; 5400 mm span; 3.00 h.
Outdoor Non-Intumescent Fireproof Coating for Steel Structure – Outdoor non-intumescent fireproof coating for steel structures.
3 h rating: ≥33 mm; 20–22 kg/m²; 5–6 coats.
Bond strength test result: 0.11 MPa.
Fire test: 33 mm thickness; 5400 mm span; 3.00 h.
Inorganic Zinc Silicate Primer (2K) – Two-component inorganic zinc silicate primer for long-term steel corrosion protection with cathodic protection.
For blast-cleaned steel; surface preparation Sa 3 (not lower than Sa 2.5) is specified.
Fast drying at 25°C, RH 70–85%: touch dry 10 min; hard dry 2 h; cured 24 h.
Mix ratio 28:7; thinner X-11 inorganic zinc thinner (5–20%); compatible with epoxy/PU coating systems.
Epoxy Zinc Primer (2K, C6-Modified) – Two-component epoxy zinc primer (C6-modified) for cathodic-protection priming.
Salt spray resistance 1300 h (as stated).
Theoretical consumption 0.25 kg/m² at 50 µm DFT (losses not included).
For offshore platforms, underwater steel, pipelines, oil tanks, bridges, and petrochemical steel structures.
Protect. Perform. Endure. – Advanced Coatings for Industrial Excellence.
© 2025 All Rights reserved Anhui HUILI Coating Technology Co., Ltd. | Privacy Policy